Zanussi Freezer 113186 User Manual

RANGE  
COMPOSITION  
Zanussi Professional have designed and  
produced a complete range of refrigerated  
tables, that combines the dual function of  
worktop and refrigerated table. This  
versatility allows notable savings in space  
whilst offering functional and modular  
solutions to kitchen requirements.  
The main benefit of this innovative new range  
is total flexibility: you have the possibility to  
compose your table to your exact personal  
requirements. You can order each individual  
unit and combine them together: structure,  
top, door, drawer and refrigeration unit.  
We offer a basic range of 38 models but the  
choice is infinite.  
The range presented here consists of 3  
models with a temperature from -13° to  
-22°C. Models are available with 2 doors;  
and 3 doors.  
113187  
PT E SERIES  
ZANUSSI  
ACTIVE FREEZER TABLES  
P R O F E S S I O N A L  
FUNCTIONAL AND  
CONSTRUCTION  
FEATURES  
Constructed entirely in AISI 304 stainless  
steel with satin finish and polished interior  
guaranteeing maximum reliability. 2"  
height-adjustable AISI 304 stainless steel  
feet (-15 to +80 mm). Completely removable  
grid support structure in AISI 304 stainless  
steel  
The worktop has a height of 50 mm and is  
slotted into place for easy removal or  
replacement with a different type of top  
(supplied on request).  
High-density expanded polyurethane  
foam, 60 mm in thickness, with  
cyclopenthane injection, guarantees  
exceptional, long-term insulation and notable  
energy savings.  
The design of the refrigeration unit allows  
maximum usage of the available space in the  
compartment. It is also mounted on a pull-out  
system to facilitate maintenance and  
cleaning.  
Electronic control panel - ACTIVE -  
allowing the Perfect Food Conservation: 4  
temperature probes in 4 different locations  
are controlled by the electronic panel; even if  
one of these probes is broken the optimal  
conservation temperature is maintained.  
TECHNICAL DATA  
CHARACTERISTICS  
MODELS  
TRF132AE  
113186  
TRF183AE  
113187  
Operating temperature - min/max °C  
Operating mode  
Gross capacity (D.I.N. 8952) - l.  
External dimensions - mm  
width  
depth/with open doors  
height  
N° and type of door  
Door hinges  
N° and type of grids (included)  
Compressor power - HP  
N° defrost in 24 hrs.  
Refrigerant type  
Refrigerant quantity - g.  
Refrigeration power - W  
Power - kW  
-22/-15  
Ventilated  
291  
-22/-15  
Ventilated  
440  
1274  
700, 1110  
850  
1759  
700, 1110  
850  
2
3
1 Left+1 Right  
2, GN 1/1  
3/4  
1 Left+2 Right  
3, GN 1/1  
3/4  
4/16'  
R404a  
280  
4/16'  
R404a  
280  
925  
925  
installed-electric  
Noise level - dBA  
Net weight - kg.  
Power supply - V, phases, Hz  
0.75  
58  
129  
0.8  
58  
152  
230 V, 1N, 50  
230 V, 1N, 50  
INCLUDED ACCESSORIES  
1/1 GN GREY "RILSAN" GRID  
2
3
 
ACTIVE FREEZER TABLES  
PT E SERIES  
The new electronic control allows the  
defrosting cycles to activate only when it is  
necessary, it means that if the evaporator is  
covered with ice, a defrosting cycle will be  
activated, if it is clear no cycle is performed.  
The smart defrosting assures a better  
utilisation of the appliance and a 5%  
Possibility to have a qualitative evaluation  
regarding the utilisation of the appliance  
based on the working condition of the major  
components (evaporator, condenser,  
compressor).  
The new central position of the  
refrigeration unit allows perfect air circulation  
in the different compartments and  
temperature uniformity.  
These appliances are suitable for use in  
tropical climates (+43°C) ensuring high  
performance even in extreme ambient  
conditions.  
The base, with water drain, is pressed and  
features rounded internal corners to  
guarantee perfect cleaning.  
The refrigerated tables feature: reversible,  
self-closing doors; recessed ergonomical  
handles.  
CFC and HCFC free.  
All models comply with the standards  
required by the main international approval  
bodies and are H marked.  
reduction in energy consumption.  
Alarm service allows 24 h per day self  
diagnostics in order to use the fridge in the  
best way. Possibility to connect the appliance  
to a computer for monitoring the events  
HACCP: monitoring the temperature 24 h  
per day and keeping record of the  
temperature when over the critical limit. Easy  
consultation of the display and sound alarm.  
OPTIONAL ACCESSORIES  
ACCESSORIES  
MODELS  
TRF132AE  
113186  
TRF183AE  
113187  
1/1 GN GREY "RILSAN" GRID  
881435  
880539  
880090  
881499  
811451  
881040  
881038  
881532  
881435  
880539  
880090  
881499  
811451  
881040  
881038  
881532  
2 WHEELS FOR REFRIGERATORS/REFRIG.TABLES  
KIT HACCP ADV.CONNECTION-REF.ELECTRONIC  
LOCK FOR REFRIGERATED COUNTERS  
PLASTIC CONTAINER GN 1/1 H=100 MM  
PLASTIC CONTAINER GN 1/1 H=150 MM  
PLASTIC CONTAINER GN 1/1 H=65 MM  
PRINTER FOR HACCP BASIC VERSION  
ZANUSSI  
P R O F E S S I O N A L  
DBBA1  
2009-07-02  
The Company reserves the right to alter technical specifications without prior notice.  
 
ACTIVE FREEZER TABLES  
PT E SERIES  
113186  
LEGEND  
TRF132AE  
113186  
D - Water drain  
16mm  
EI - Electrical connection  
230 V, 1N, 50  
ZANUSSI  
P R O F E S S I O N A L  
DBBA1  
2009-07-02  
The Company reserves the right to alter technical specifications without prior notice.  
 
ACTIVE FREEZER TABLES  
PT E SERIES  
113187  
LEGEND  
TRF183AE  
113187  
D - Water drain  
16mm  
EI - Electrical connection  
230 V, 1N, 50  
ZANUSSI  
P R O F E S S I O N A L  
DBBA1  
2009-07-02  
The Company reserves the right to alter technical specifications without prior notice.  
 

Weider Fitness Equipment XP600 User Manual
Weider Home Gym WESY81080 User Manual
Weil McLain Swimming Pool Heater WMBH 95 User Manual
Whirlpool Air Conditioner ACC602XT User Manual
Whirlpool Dishwasher ADP 4501 5 User Manual
Williams Sound Switch MOD 232 User Manual
Wolf Appliance Company Ventilation Hood PL462212 User Manual
Xantrex Technology Battery Charger Xantrex Battery Monitor User Manual
Xerox Fax Machine F2121 User Manual
Xpelair Fan FR22 30 User Manual