Xpelair Ventilation Hood DX100H User Manual

GB  
F
Installation and maintenance instructions  
DX100  
Standard  
DX100PC Pull Cord  
D
DX100T  
DX100H  
Time  
r
NL  
I
Humidistat  
DX100HP Humidistat and Pull Cord  
DX100PIR Integral Body Movement Sensor  
DX100VTD Delay Timer  
S
GR  
N
Toilet/Bathroom 100mm/4" Fan Range  
Retain for future reference  
SE  
A
®
 
H
J
DX100H & DX100HP  
I
K
DX100T  
DX100PIR  
L
3
 
Installing the fan  
What the installer will need  
GB  
These appliances are intended for connection to  
fixed wiring. Check that the electrical rating shown  
on each fan matches the mains supply.  
A double pole isolating switch with a minimum  
contact gap of 3mm (wall or ceiling mounted).  
Xpelair  
If metal switch boxes are used, earthing  
regulations must be followed.  
Toilet/Bathroom  
Fans DX100,  
DX100PC, DX100T,  
DX100H, DX100HP  
DX100PIR &  
DX100VTD  
installation &  
operating  
instructions  
THESE APPLIANCES ARE DOUBLE  
INSULATED AND DO NOT REQUIRE AN  
EARTH CONNECTION.  
Suitably rated 2-core cable (DX100,  
DX100PC, DX100HP and DX100PIR).  
All installations must be supervised by a qualified  
electrician. Installations and wiring must conform  
to current IEE Regulations (UK), local or  
Suitably rated 3-core cable (DX100T, DX100H  
and DX100VTD).  
3mm electrician's screwdriver and no.1 or 2  
Pozdriv screwdrivers.  
appropriate regulations (other countries).  
If you have any queries before installing these  
products or after they have been installed, call  
the Xpelair Technical Hotline  
+44 (0) 8709 000430. Our engineers are there to  
help you during normal office hours (UK only)  
and may be faxed at all other times on  
+44 (0) 8709 000530.  
A wall or ceiling on/off switch with built-in  
indicator light (DX100, DX100T, and  
DX100VTD).  
To prevent a possible hazardous situation  
from water ingress, a condensation trap  
(Xpelair no. XCT100) must be fitted as  
close as possible to the fan in all situations  
where any section of the duct work is  
positioned higher than the fan itself.  
Please leave this leaflet  
with the fan for the  
benefit of the user  
Customers outside the UK should contact your  
local Xpelair distributor.  
Description  
If wall mounting the fan, you will also need  
Xpelair fans have the following features:  
Masonry drill, hammer & chisel (or core drill  
equipment if available).  
Universal mounting kit allows window/ wall  
panel/ ventilation shaft/ ceiling mounting  
options.  
Mortar to make good the hole if required.  
If window mounting the fan  
Single speed extraction  
You will need a window pane between 3mm  
and 6mm thick (preferably 4mm).  
DX100  
Operate the fan using an on/off switch  
(not supplied).  
Do not install in glass 3mm thick if the window  
pane area is more than 0.2sq.m.  
DX100PC  
If installing in sealed double glazing, a  
Operate the fan using integral pull cord.  
specially manufactured unit should be  
obtained from the glazing manufacturer. You  
will also require a special kit, Xpelair Cat. ref.  
DXDG.  
DX100T  
Built-in timer automatically operates fan for a  
preset delay of up to 30 minutes.  
If installing in sash windows, you should  
DX100H  
mount the fan in the upper window. Secure the  
upper sash in the closed position and fit stops  
just below the level of the fan, to prevent  
damaging it when the sash is raised.  
Operates either when triggered automatically  
by the humidity sensor or when turned on at  
the on/off switch (light indicates when fan is  
operating in manual mode).  
If installing in a panel which is between 9mm  
and 46mm thick, you will need a special kit,  
Xpelair Cat. ref. DXDG. Do not install these  
fans in a panel which is more than 46mm  
thick.  
DX100HP  
Operates either when triggered automatically  
by the humidity sensor or when turned on  
using the integral pull cord switch (light  
indicates when fan is operating in manual  
mode). Built-in timer automatically operates  
fan for a preset delay of up to 20 minutes.  
If ceiling mounting the fan  
You will need to use the appropriate ancillaries  
for termination. These items are available from  
Xpelair.  
DX100PIR  
1. WT10 - Termination ducting kit.  
An integral body movement sensor operates  
the fan as long as movement is detected.  
Built-in timer automatically operates fan for a  
preset delay of up to 20 minutes.  
2. CFWG100 - Soffit board termination grille  
(white or brown).  
3. FD100 / 3 and FD100 / 6 - Flexible ducting.  
DX100VTD  
Where to locate the fan  
Operate the fan using the on/off switch (not  
supplied). The fan will not start for  
approximately 2.5 minutes (+/- 27%).  
After this time, the fan will operate. When the  
fan is switched off, it will continue to operate  
for approximately 7.5 minutes (+/- 27%).  
Locate it as high as possible.  
At least 110mm from the edges of the  
mounting surface to the centre of the hole.  
As far away as possible from and opposite to  
the main source of air replacement to ensure  
4
 
airflow across the room (e.g. opposite the  
internal doorway).  
Near the source of steam or odours.  
flexible 2-core cable complete with 3 pin plug for  
insertion into an approved 10 amp GPO or  
directly wired through an approved 10A wall-  
mounted surface switch with at least 3mm  
clearance between contacts.  
Not where ambient temperatures are likely  
to exceed 50˚C.  
For Australia only (DX100T, DX100H & DX100VTD)  
These models are permanently connected to the  
supply and operation is controlled by a remote  
switch. They should be directly wired to the  
supply through an approved 10amp wall mounted  
surface switch with at least 3mm clearance  
between contacts.  
If installed in a kitchen fans must not be  
mounted immediately above a cooker hob,  
or eye level grill.  
If installing in a room containing a fuel  
burning device which has a non-balanced  
flue, it is the installer's responsibility to  
ensure that there is enough replacement  
air to prevent fumes being drawn down the  
flue when the fan is operating up to  
maximum extract.  
WARNING : CHILDREN SHOULD NOT PLAY WITH  
THE APPLIANCE AND ENSURE THAT YOUNG  
CHILDREN AND THE INFIRM ARE SUPERVISED  
Preparing the hole  
If working above ground floor level,  
appropriate safety precautions must be  
observed.  
Refer to Building Regulations for specific  
requirements.  
WARNING: EYE PROTECTION MUST BE  
WORN DURING ALL DRILLING AND  
CHISELLING OPERATIONS.  
Exhaust air must not be discharged into a  
flue used for exhausting of fumes from  
appliances supplied with energy other than  
electric. Requirements of all authorities  
concerned must be observed for exhaust  
air discharge and intake flow rates.  
If installing in a wall  
1. Check there are no buried pipes or cables  
in the wall or obstructions on the outside  
e.g. electricity, gas, water.  
If in doubt, seek professional advise.  
When intended for use in possible  
chemical corrosive atmospheres, consult  
out Technical Service Department. (For  
overseas markets contact your local  
Xpelair distributor).  
2. Mark on the wall the centre of the duct hole.  
3. Use this centre to mark a circle to suit the  
wall duct (115mm diameter).  
If core drill equipment is available:  
4a.Use as directed by core drill manufacturer.  
DX100PIR Only - Siting must ensure  
detection of movement. Care should be  
taken to avoid obstruction that may affect  
detection beams A .  
If core drill equipment is not available:  
4b.Drill a centre hole right through the wall.  
5. Cut the hole. Do not cut right through the  
wall. (The recommended method is to drill a  
series of holes, close together, around the  
edge of the cutting line and remove the brick  
between the holes with a chisel).  
Installing the isolating switch and cables  
1. Check that the electrical rating shown inside  
the back plate matches your mains supply.  
2. Check there are no buried pipes or cables  
e.g. electricity, gas, water behind the switch  
location (in the wall or above the ceiling).  
If in doubt, seek professional advise.  
6. Go outside and cut a hole in the outer wall,  
repeating the process described above.  
7. Cut ducting to the correct length if required.  
The wall tube supplied is telescopic and can  
extend to 300mm maximum.  
3. Isolate the mains supply.  
4. Lay in the cable from the isolating switch to  
the fan location via the on/off switch  
(if required).  
5. Lay in the cable from the isolating switch to  
the point of connection to the mains supply.  
6. Install the isolating switch and on/off switch  
(if required).  
7. Make all connections within the isolating  
switch and the on/off switch (if required).  
8. Fit the ducting. Ensure that the duct slopes  
down away from the fan to allow drainage of  
any incoming rain water to the outside.  
9. Make good the hole. Allow the mortar to set  
before continuing the fan installation.  
If installing in a window or panel  
1. Cut a hole, 125mm in diameter or if installing  
in a window, obtain a ready cut pane.  
Note: on/off switch must be situated so that it  
cannot be touched by persons making use of  
the bath or shower.  
2. The centre of the hole should be at least  
110mm away from the edge of the panel or  
pane of glass.  
WARNING : DO NOT MAKE ANY  
CONNECTIONS TO THE ELECTRICAL  
SUPPLY AT THIS STAGE.  
If installing in a ventilation shaft  
1. Check there are no buried pipes or cables  
in the ventilation shaft.  
If in doubt, seek professional advise.  
For Australia only (DX100, DX100PC. DX100HP &  
DX100PIR)  
2. Cut a hole 110mm in diameter, in the side of  
the shaft.  
Connection to the supply can be made by a  
5
 
3. If the shaft has cavity wall, use the wall tube  
to bridge the cavity.  
3. Making sure that the back draught shutter is  
level, mark the positions of the two fixing  
holes in the top right hand and bottom left  
hand corners.  
GB  
4. Fit ducting and condensation trap if  
necessary, positioning condensation trap as  
near to the fan as possible.  
Xpelair  
4. Remove the back draught from the wall duct.  
Toilet/Bathroom  
Fans DX100,  
DX100PC, DX100T,  
DX100H, DX100HP  
DX100PIR &  
DX100VTD  
installation &  
operating  
instructions  
If installing in a ceiling  
5. Drill screw holes in these positions, and fit  
the remaining wall plugs.  
1. Check there are no buried pipes or cables  
in the ceiling/joists etc.  
If in doubt, seek professional advise.  
6. Holding open the top and bottom vanes, refit  
the back draught shutter and fasten it to the  
wall using the pointed and self-tapping  
screws. Do not over tighten screws.  
2. Cut a hole 115mm diameter.  
Preparing the fan for installation  
7. Make sure that the vanes open  
and shut freely.  
Remove the front cover by pressing the release  
catches located on the sides of the unit with a  
3mm screwdriver, whilst pulling the front cover  
forward L  
If installing in window or panel  
Sealing the hole E  
Please leave this leaflet  
with the fan for the  
benefit of the user  
1. If installing in a window or panel no more  
than 9mm thick, fit the white rubber gasket  
around the edge of the hole. If installing in a  
panel or sealed double glazing more than  
9mm thick, a DXDG double glazing kit is  
required. Follow the instructions supplied with  
the special kit.  
Mount the fan in the hole  
If working above ground floor level,  
appropriate safety precautions must be  
observed.  
If installing in a wall, ceiling or vent  
Mark the position of the back plate B  
Attach the back draught shutter to the  
spacer F  
1. Hold the backplate so that the terminal block  
faces you in the top left hand corner and the  
lip points towards the hole.  
1. Holding the top and bottom vanes, insert the  
back draught shutter 2 into the spacer 3 so  
that the fixing holes in the top right and  
bottom left hand corners match those on the  
spacer.  
2. Carefully insert the lip into the wall  
duct/ceiling or vent shaft.  
3. Adjust the position of the back plate until it is  
level.  
2. Insert two of the flat ended self-tapping  
screws provided and fasten the back draught  
shutter to the spacer.  
4. Mark on the wall/ceiling or vent shaft the  
positions of the three fixing holes in the back  
plate.  
Mount the fan in the window G  
5. Remove the back plate from the ducting.  
1. Someone else must hold the back draught  
shutter and spacer in position outside, with  
the spacer against the glass.  
6. Drill screw holes in these positions if  
necessary, and fit wall plugs if necessary.  
Mount the back plate C  
2. Make sure that the two raised fixing holes in  
the spacer are horizontal and are positioned  
within the hole.  
1. Push the ribbed gasket (RG100) onto the lip  
of the back plate 1  
3. From inside, hold the back plate so that the  
terminal block faces you in the top left hand  
corner and the lip points towards that hole.  
2. If installing in a ceiling or vent, push the  
larger diameter piece of the telescopic wall  
tube onto the ribbed gasket. Cut the tube to  
the required length first, if necessary.  
4. Align the holes in the back plate with those in  
the spacer.  
3. If wiring the fan from behind, remove  
knockout. Feed the mains cable through the  
cable entry hole in the back plate to the  
terminals D.  
5. Insert two of the flat ended self-tapping  
screws provided in the fixing holes, and  
fasten the back plate to the spacer. Do not  
overtighten the screws.  
4. If wiring from above, leave the cable free to  
be fitted into labyrinth.  
Wire the electrical connections  
5. Insert the lip of the back plate into the wall  
duct/ceiling or vent shaft as before.  
Make sure the mains supply is isolated,  
1. Wire the fan as shown in H check the fan  
model to diagram, feeding the cable between  
the two raised pegs, if wiring from above, and  
through labyrinth to terminal block.  
6. Fasten the back plate to the wall/ceiling or  
vent shaft using appropriate fasteners. If  
using screws, do not overtighten the  
screws.  
2. Switch off the mains electrical supply and  
remove fuses  
Mount the back draught shutter  
1. Peel the backing from the foam strip supplied  
and attach it around the outside of the lip on  
the back draught shutter.  
3. Connect the cable from the isolating switch to  
the electrical supply wiring.  
For fixed wiring circuits the protective  
2. Go outside. Holding open the top and bottom  
vanes, insert the lip into the wall duct.  
6
 
fuse for the appliance must not exceed  
5A.  
Cleaning (recommended once a month)  
A QUALIFIED ELECTRICIAN MUST CARRY  
OUT ALL CLEANING.  
DX100T only  
I
To adjust the over-run period turn the control  
(T) clockwise to increase and anti-clockwise  
to decrease.  
1. Before cleaning, isolate the fan completely  
from the mains supply.  
2. Remove the front cover by pressing the  
release catches located on the sides at the  
unit with a 3mm screwdriver, whilst pulling the  
front cover forward L  
DX100H & DX100HP only  
J
Humidity operation is factory set at approx.  
70% Relative Humidity (RH), but can be  
adjusted between 50% and 90% RH by  
control(H).  
3. To clean the front cover, either wipe it with a  
damp, lint free cloth or wash it in warm soapy  
water. Thoroughly dry the front cover and  
refit.  
Time delay is factory set at approx. 20 mins,  
but can be adjusted by control (T).  
4. Do not immerse the fan in water or other  
liquids to clean any other parts of the fan.  
Both controls are adjustable. Turn the controls  
clockwise to increase time or RH, and anti-  
clockwise to decrease.  
5. Never use strong solvents to clean the fan.  
DX100PIR only K  
6. Apart from cleaning, no other maintenance is  
required.  
Adjust the overrun period with control (T).  
Turn screwdriver clockwise to increase and  
anti-clockwise to decrease.  
All fans  
If wiring from above cut out the cable entry  
slot marked on top of the front cover.  
Fit the front cover by aligning it square to the  
duct and pushing it onto the duct until the  
release catches snap into the slots on the  
front cover.  
Using the fan  
DX100 & DX100VTD only  
Operate the fan using the on/off switch.  
Repeat to switch off.  
DX100PC only  
Operate the fan by pulling and releasing the  
cord. Repeat to switch off.  
DX100T only  
Operate the fan using the on/off switch. When  
the switch is turned off, the fan continues to  
operate for the adjustable time delay.  
DX100H only  
Manual mode: use the on/off switch. When  
you switch off, the fan goes into automatic  
mode after the time delay (light indicates  
when fan is operating in manual mode).  
Automatic mode: fan operates when relative  
humidity rises and turns off again when  
humidity drops.  
DX100PIR only  
The sensor detects movement in the room  
and activates the fan. When movement is  
sensed, the fan will run for a pre-set overrun  
period and any further movement sensed will  
re-start the sequence. This ensures that the  
room is only ventilated during and  
immediately after use. When the fan is first  
installed there will be a stabilising period  
of approximately five minutes. During this  
time the fan will run for up to two minutes.  
7
 

Weslo Treadmill WLTL29014 User Manual
Western Digital Computer Drive WD10EARX User Manual
Western Telematic Surge Protector TAN 1005 User Manual
Whirlpool Air Conditioner AC1052XS User Manual
Whirlpool Washer Dryer LSC8244EQ0 User Manual
Windsor Carpet Cleaner 10052290 User Manual
Yamaha Speaker System AS312 User Manual
Zanussi Flat Panel Television M260VP User Manual
Zanussi Oven ZOB 593 User Manual
Zanussi Washer ZT 1012 User Manual